{"id":244,"date":"2026-09-09T22:09:17","date_gmt":"2026-09-09T14:09:17","guid":{"rendered":"https:\/\/graphicdesignerph.com\/temporary-bi-sonjend\/?post_type=product&#038;p=244"},"modified":"2026-09-09T22:09:17","modified_gmt":"2026-09-09T14:09:17","slug":"400t-h-automatic-chemistry-analyzer","status":"publish","type":"product","link":"https:\/\/graphicdesignerph.com\/temporary-bi-sonjend\/index.php\/product\/400t-h-automatic-chemistry-analyzer\/","title":{"rendered":"400T\/H Automatic Chemistry Analyzer"},"content":{"rendered":"<p><strong>Features:<\/strong><\/p>\n<p>1. 49 sample positions<br \/>\n2. 56 reagent positions.<\/p>\n<p>3. 120 reaction cuvettes.<\/p>\n<p>4. 400 tests per hour.<\/p>\n<p>5. Probe with anti-collision function, liquid level dectection function.<\/p>\n<p><img decoding=\"async\" class=\" lazyloaded\" title=\"\" src=\"https:\/\/ikrorwxhqjrilj5q.ldycdn.com\/cloud\/lpBprKkmljSRllkjpqrjio\/BK.jpg\" alt=\"high-throughput chemistry analyzer\" width=\"1089\" height=\"485\" border=\"0\" hspace=\"0\" vspace=\"0\" data-original=\"\/\/ikrorwxhqjrilj5q.ldycdn.com\/cloud\/lpBprKkmljSRllkjpqrjio\/BK.jpg\"><\/p>\n<p><strong>Technical Parameters:<\/strong><\/p>\n<div class=\"sliderTable mt10 mb10 sliderTable-index1\">\n<div class=\"inner\">\n<table align=\"left\">\n<tbody>\n<tr class=\"ue-table-interlace-color-single firstRow\">\n<td>Model<\/td>\n<td colspan=\"2\">BK-410<\/td>\n<\/tr>\n<tr class=\"ue-table-interlace-color-double\">\n<td rowspan=\"4\">Overall<br \/>\nPerformance<\/td>\n<td>Throughput<\/td>\n<td>400 Tests\/hour, ISE(Optional)<\/td>\n<\/tr>\n<tr class=\"ue-table-interlace-color-single\">\n<td>Analysis Method<\/td>\n<td>End-point, Fixed-time, Rate(Kinetic), Turbidimetry<\/td>\n<\/tr>\n<tr class=\"ue-table-interlace-color-double\">\n<td>Certificates<\/td>\n<td>CE, FDA, ISO9001, ISO14001, ISO13485<\/td>\n<\/tr>\n<tr class=\"ue-table-interlace-color-single\">\n<td>System<\/td>\n<td>Optional open or close system, continuous working for 24 hours<\/td>\n<\/tr>\n<tr class=\"ue-table-interlace-color-double\">\n<td rowspan=\"7\">Sample&amp;Reagent System<\/td>\n<td>Sample Positions<\/td>\n<td>49 sample positions<\/td>\n<\/tr>\n<tr class=\"ue-table-interlace-color-single\">\n<td>Reagent Position<\/td>\n<td>56 reagent positions<\/td>\n<\/tr>\n<tr class=\"ue-table-interlace-color-double\">\n<td>Sample Volume<\/td>\n<td>2~70\u03bcl<\/td>\n<\/tr>\n<tr class=\"ue-table-interlace-color-single\">\n<td>Reagent Volume<\/td>\n<td>20~350\u03bcl<\/td>\n<\/tr>\n<tr class=\"ue-table-interlace-color-double\">\n<td>Probe<\/td>\n<td>With anti-collision function, liquid level detection function<\/td>\n<\/tr>\n<tr class=\"ue-table-interlace-color-single\">\n<td>Probe Washing<\/td>\n<td>Automatic washing interior and exterior<\/td>\n<\/tr>\n<tr class=\"ue-table-interlace-color-double\">\n<td>Reagent Cooling<\/td>\n<td>2~12\u2103 for 24 hours<\/td>\n<\/tr>\n<tr class=\"ue-table-interlace-color-single\">\n<td rowspan=\"4\">Reaction System<\/td>\n<td>Temperature Control<\/td>\n<td>37\u00b10.2\u2103, real-time monitoring<\/td>\n<\/tr>\n<tr class=\"ue-table-interlace-color-double\">\n<td>Cuvettes<\/td>\n<td>120 reusable cuvettes<\/td>\n<\/tr>\n<tr class=\"ue-table-interlace-color-single\">\n<td>Mixer Probe<\/td>\n<td>Independent stirring, automatic frequency conversion<\/td>\n<\/tr>\n<tr class=\"ue-table-interlace-color-double\">\n<td>Washing<\/td>\n<td>Automatic cuvettes washing<\/td>\n<\/tr>\n<tr class=\"ue-table-interlace-color-single\">\n<td rowspan=\"4\">Optical System<\/td>\n<td>Light Source<\/td>\n<td>Halogen lamp, water-cooling<\/td>\n<\/tr>\n<tr class=\"ue-table-interlace-color-double\">\n<td>Spectrophotometry<\/td>\n<td>Post-spectral spectrophotometry<\/td>\n<\/tr>\n<tr class=\"ue-table-interlace-color-single\">\n<td>Wavelength<\/td>\n<td>340~800nm, \uff1c\u00b11nm<\/td>\n<\/tr>\n<tr class=\"ue-table-interlace-color-double\">\n<td>Absorbance<\/td>\n<td>0~3.5Abs<\/td>\n<\/tr>\n<tr class=\"ue-table-interlace-color-single\">\n<td rowspan=\"2\">Calibration&amp;QC<\/td>\n<td>Calibration<\/td>\n<td>Linear: K factor, 1-point, 2-point and multipoint linear<\/p>\n<p>Non-Linear: Spline, Polygon, Index, Ogarithm, Logit-4P, Logit-5P<\/td>\n<\/tr>\n<tr class=\"ue-table-interlace-color-double\">\n<td>Quality Control<\/td>\n<td>Real-time QC, Westgard multi rule, Cumulative sum check, Twin plot(2D)<\/td>\n<\/tr>\n<tr class=\"ue-table-interlace-color-single\">\n<td rowspan=\"4\">Data Management<\/td>\n<td>Software<\/td>\n<td>Windows 7\/8\/10, 32 or 64 bit<\/td>\n<\/tr>\n<tr class=\"ue-table-interlace-color-double\">\n<td>LIS System<\/td>\n<td>Bi-direction, support HL7 protocol<\/td>\n<\/tr>\n<tr class=\"ue-table-interlace-color-single\">\n<td>Interface<\/td>\n<td>LAN port access<\/td>\n<\/tr>\n<tr class=\"ue-table-interlace-color-double\">\n<td>Printer<\/td>\n<td>External, multiple reporting mode available<\/td>\n<\/tr>\n<tr class=\"ue-table-interlace-color-single\">\n<td rowspan=\"4\">Working Conditions<\/td>\n<td>Power Supply<\/td>\n<td>AC220V\u00b110%, 50\/60Hz(Standard)<\/p>\n<p>110V\u00b110%, 60Hz(Optional), 650VA<\/td>\n<\/tr>\n<tr class=\"ue-table-interlace-color-double\">\n<td>Temperature<\/td>\n<td>15~30\u2103(\u00b12\u2103)<\/td>\n<\/tr>\n<tr class=\"ue-table-interlace-color-single\">\n<td>Water Consumption<\/td>\n<td>Deionized water\uff1c11L\/h<\/td>\n<\/tr>\n<tr class=\"ue-table-interlace-color-double\">\n<td>Humidity<\/td>\n<td>40~85%<\/td>\n<\/tr>\n<tr class=\"ue-table-interlace-color-single\">\n<td rowspan=\"4\">Size&amp;Weight<\/td>\n<td>External Size(W*D*H)<\/td>\n<td>973*645*520mm<\/td>\n<\/tr>\n<tr class=\"ue-table-interlace-color-double\">\n<td>Net Weight<\/td>\n<td>96kg<\/td>\n<\/tr>\n<tr class=\"ue-table-interlace-color-single\">\n<td>Package Size(W*D*H)<\/td>\n<td>1120*780*1035mm<\/td>\n<\/tr>\n<tr class=\"ue-table-interlace-color-double\">\n<td>Gross Weight<\/td>\n<td>141kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<div><strong>Introduction:<\/strong><\/div>\n<p>The 400T\/H Automatic Chemistry Analyzer is a state-of-the-art diagnostic tool designed for high-efficiency biochemical analysis. This advanced instrument boasts an impressive array of features tailored to meet the demands of modern laboratories.<\/p>\n","protected":false},"featured_media":245,"template":"","meta":{"ngg_post_thumbnail":0},"product_brand":[],"product_cat":[42,41],"product_tag":[],"class_list":["post-244","product","type-product","status-publish","has-post-thumbnail","product_cat-clinicalanalytical-instrument","product_cat-laboratory-solution","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/graphicdesignerph.com\/temporary-bi-sonjend\/index.php\/wp-json\/wp\/v2\/product\/244","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/graphicdesignerph.com\/temporary-bi-sonjend\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/graphicdesignerph.com\/temporary-bi-sonjend\/index.php\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/graphicdesignerph.com\/temporary-bi-sonjend\/index.php\/wp-json\/wp\/v2\/media\/245"}],"wp:attachment":[{"href":"https:\/\/graphicdesignerph.com\/temporary-bi-sonjend\/index.php\/wp-json\/wp\/v2\/media?parent=244"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/graphicdesignerph.com\/temporary-bi-sonjend\/index.php\/wp-json\/wp\/v2\/product_brand?post=244"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/graphicdesignerph.com\/temporary-bi-sonjend\/index.php\/wp-json\/wp\/v2\/product_cat?post=244"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/graphicdesignerph.com\/temporary-bi-sonjend\/index.php\/wp-json\/wp\/v2\/product_tag?post=244"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}